Cybex 530S Owner’s Manual
WARNING: Serious injury could occur if these
inspection and maintenance
actions are not observed.
Inspect the drive cables regularly for signs of
wear and replace them every six to eight months
with Cybex-supplied replacement cables. See
Figure 1 for location of drive cables.
Follow the procedure below to ensure that the
cables are in good condition. NOTE: If a cable
has cracks or appears worn, it must be replaced
immediately by a qualified service technician.
Tools Required
• None
WARNING: To prevent electrical shock, be
sure that the unit is unplugged
from the electrical outlet before
performing any cleaning or
maintenance procedures.
1. Read and understand this Drive Belt Maintenance section thoroughly before proceeding to
step 2.
2. Disconnect the external power source.
A. Locate the on/off (I/O) power switch on the front of the stepper. Toggle it to the on (I) position.
B. Unplug the stepper from the power outlet.
3. Inspect the drive cables.
A. While kneeling next to the stepper push one pedal all the way to the floor.
B. Inspect the drive cable for signs of wear, cracking or discoloring.
C. Carefully return the pedal to it’s starting position.
D. Repeat procedure for other drive cable.
Drive
Cables
Figure 1
Preventive
Maintenance
Page 4-3
Drive Cable Maintenance