Cybex Arc Trainer 610A Service Manual
Service
Page 4-13
B. Using a Phillips head screwdriver, tighten the four screws securing the access cover.
See Figure 2.
Eddy Current Brake
Tools Required
• Phillips head screwdriver
• 3/16” Allen wrench
• 7/16” Socket wrench
• Work Gloves
! WARNING: Disconnect the power cord before beginning this procedure. Keep wet items away
from inside parts of the unit. Electrical shock could occur even if the unit is
unplugged.
1. Elevate the unit and disconnect the power source.
A. Plug the power cord into the power outlet.
B. Enter Test Mode.
C. Elevate the unit to a minimum of level 7 incline.
D. While the unit is elevated, turn the main power switch to the off (O) position and unplug the
power cord from the power outlet.
2. Remove the access cover.
A. Using a Phillips head screwdriver, remove the four screws securing the access cover. See
Figure 2.
B. Remove the access cover.
! WARNING: Flywheel may be hot. Wait until it cools before servicing.
3. Detach the connecting rods.
A. Using a 3/16” Allen wrench, remove the screw securing each connecting rod to each crank.
See Figure 4.
B. Place a cloth on the frame where the connecting rod will rest.
C. Rest the rod on the cloth to prevent scratches. See Figure 4.
4. Loosen the left side cover
A. Using a Phillips head screwdriver, remove the six screws and six washers securing each side
cover in place. See Figure 5.
B. Remove both side covers. NOTE: The gasket will come off with one of the side covers.
See Figure 5.